Hospital water system linked to Mycobacterium abscessus cluster
-
By
-
Meg Barbor
-
October 6, 2026
-
4 min
Clinical Report: Hospital water system linked to Mycobacterium abscessus cluster
Overview
An investigation at a Maryland hospital identified 10 patients with Mycobacterium abscessus-positive cultures collected between March 2023 and June 2024, followed by an additional patient identified in September 2024. Genomic and epidemiologic findings linked the cluster to the hospital water system, with ice machines implicated as a probable source. Follow-up samples from locations with point-of-use filters showed no bacterial growth.
Background
M. abscessus is a nontuberculous mycobacterium found naturally in soil, dust and water. It can cause skin and soft tissue infections, bloodstream infections and pulmonary disease and can be difficult to treat because of intrinsic drug resistance.
Health care–associated outbreaks have previously been linked to contaminated water sources. After hospital infection prevention staff identified an initial case in May 2024, investigators reviewed clinical and epidemiologic data, collected environmental samples and compared patient and environmental isolates using whole-genome sequencing.
Data Highlights
Measure | Finding |
|---|---|
Patients identified | 10 with positive cultures collected between March 2023 and June 2024; an additional patient identified in September 2024 brought the total to 11 |
Clinical classification | 6 clinical infections; 5 likely colonization or specimen contamination |
Antimicrobial treatment | 6 patients received treatment after positive cultures |
Environmental sampling before mitigation | 47 samples from 19 hospital locations |
Environmental samples positive for M. abscessus | 18 of 47 (38%) |
Genomic clusters | 5 subclusters; 4 included both patient and environmental isolates |
Mortality | 1 patient died within 60 days of the first positive culture; the death was not attributed to M. abscessus |
Key Findings
Investigators classified six patients as having clinical infections and five as likely representing colonization or specimen contamination. The patients had a median age of 40 years.
Before mitigation, environmental sampling included bulk water and swabs from faucets, sinks and ice machines. M. abscessus was detected throughout the hospital, including in ice machines.
Four of five genetic subclusters contained both patient and environmental isolates, supporting a link to the hospital water system.
One patient isolate exactly matched a sample from a postanesthesia care unit ice machine. Two other patient isolates were closely related to environmental samples from the same area.
Combined genomic and epidemiologic findings confirmed colonization of the hospital water system and implicated ice machines as a probable infection source.
Follow-up samples from locations with point-of-use filters showed no bacterial growth. The organism remained detectable after hospital-wide flushing and increased disinfectant levels, suggesting those measures produced only temporary reductions.
Clinical Implications
The hospital implemented water flushing, increased supplemental disinfectant levels, restrictions on tap water and ice machine use, staff sink-safety education and point-of-use filters in high-risk areas.
Filters appeared to be the most effective intervention, although they are expensive and require regular inspection and replacement. Investigators emphasized that established biofilm makes M. abscessus difficult to eliminate from water systems.
The hospital updated its water management plan to include more frequent building flushing, residual disinfectant testing and specific M. abscessus testing. Investigators considered swift removal of potential exposure sources from patient areas likely important in preventing additional infections.
Conclusion
The investigation linked the cluster to the hospital water system and implicated ice machines as a probable source. Persistent detection after flushing and increased disinfectant levels highlighted mitigation challenges. Investigators emphasized robust water management, sink-safety education and prompt action to reduce patient exposure.
Related Resources & Content
Hospital water system linked to Mycobacterium abscessus cluster — Meg Barbor — IDSA Reporter — October 6, 2026 — https://idsareporter.com/issues/2026/october-2026/hospital-water-system-linked-to-mycobacterium-abscessus-cluster/.
Investigation of Mycobacterium abscessus Cluster in Hospital, Maryland, USA, 2024 — Ludmer S, Duwell M, Harris T, et al — Emerging Infectious Diseases — Published online August 5, 2026; September 2026;32(9):1397-1401 — https://doi.org/10.3201/eid3209.260093.
Based on findings from:
Hospital water system linked to Mycobacterium abscessus cluster
Meg Barbor. Idsa Reporter, 2026.
https://idsareporter.com/issues/2026/october-2026/hospital-water-system-linked-to-mycobacterium-abscessus-cluster/
This content is an AI-generated, fully rewritten summary based on a published scholarly article. It does not reproduce the original text and is not a substitute for the original publication. Readers are encouraged to consult the source for full context, data, and methodology.