Objective:

To identify factors influencing capsulotomy diameter deviation and develop a predictive regression model for actual capsulotomy diameter in femtosecond laser-assisted cataract surgery, enhancing preoperative planning.

Approach:
    Key Findings:
    • Discrepancies between programmed and actual capsulotomy diameters were observed.
    • Factors influencing diameter deviation included ocular biometric parameters and surgical technique.
    • A predictive regression model was developed to assist in preoperative planning, potentially improving surgical outcomes.
    Interpretation:

    The study highlights the importance of accurately achieving capsulotomy size to prevent complications and enhance visual outcomes post-surgery.

    Limitations:
    • Retrospective design may introduce selection bias.
    • Limited sample size of 47 eyes may affect generalizability.
    • Potential measurement bias in assessing capsulotomy diameter.
    • Confounding factors may not have been fully accounted for.
    Conclusion:

    The findings underscore the need for improved predictive models to enhance capsulotomy accuracy in femtosecond laser-assisted cataract surgery.