CPAP changes may precede choroidal detachment - Summary - MDSpire
Coming Soon: Introducing MDSpire News. Learn more
Conexiant’s news site is now MDSpire News. Learn more

CPAP changes may precede choroidal detachment

  • By

  • Andrea Surnit

  • October 22, 2026

  • 4 min

Share

Objective:

To describe a case of choroidal detachment occurring after changes to continuous positive airway pressure (CPAP) therapy and discuss a possible relationship.

Approach:
  • Case: A 76-year-old man with obstructive sleep apnea had used CPAP for 8 years. His pressure was increased and a new oronasal mask reduced leakage about 20 weeks before presentation.
  • Evaluation and treatment: The patient developed left-eye visual symptoms and was found to have a massive choroidal effusion. He received topical dexamethasone and cyclopentolate; dorzolamide plus timolol was added when the detachment progressed and intraocular pressure rose.
  • Follow-up: CPAP was continued. Ocular findings improved over 16 weeks with treatment, and visual acuity and eye anatomy continued to improve by week 18.
Key Findings:
  • The choroidal detachment developed after CPAP pressure was increased and mask leakage was reduced.
  • The detachment progressed to a kissing configuration, with visual acuity declining to hand movements and intraocular pressure rising to 27 mmHg.
  • By week 16, the detachment had resolved anatomically; at week 18, visual acuity was 0.4 and intraocular pressure was 16 mmHg.
  • The authors proposed that positive airway pressure might impair choroidal venous drainage, but noted that the mechanism and relationship to CPAP remain unproven.
Interpretation:

The authors suggested considering CPAP as a possible contributor in patients with otherwise unexplained choroidal detachment, while emphasizing that this single case cannot establish causation.

Limitations:
  • CPAP continued while the ocular findings improved during corticosteroid, cycloplegic, and intraocular-pressure-lowering treatment.
  • Thyroid-associated orbitopathy was not formally excluded because thyroid function testing was not performed.
  • MRI, MRA, and digital subtraction angiography were not performed; these are more sensitive than CT for some low-flow vascular abnormalities.
  • Available evidence did not directly link CPAP therapy with episcleral venous pressure.
Conclusion:

The report describes a temporal association between CPAP adjustments and choroidal detachment, but the cause remains uncertain.