1
Surgical meshes are categorized into synthetic, biologic, and hybrid types, each with distinct mechanical properties and host tissue responses.
-
2
Strattice™ is a non-crosslinked biologic mesh that minimizes inflammation and encapsulation, while OviTex™ is a hybrid mesh combining biologic and synthetic materials.
-
3
The study aimed to compare the mechanical properties and host responses of OviTex 1S-P, OviTex 2S-R, and Strattice using in vitro and in vivo methods.
-
4
In vitro tests included scanning electron microscopy and tensile testing to assess mechanical strength and morphology of the mesh samples.
-
5
In vivo characterization utilized rodent and primate models to evaluate host biological responses and mechanical strength post-implantation.