Relationship between mid-term intraocular pressure and aqueous flare measurements in micropulse transscleral cyclophotocoagulation: a retrospective observational analysis - Takeaways - MDSpire
Coming Soon: Introducing MDSpire News. Learn more
Conexiant’s news site is now MDSpire News. Learn more

Relationship between mid-term intraocular pressure and aqueous flare measurements in micropulse transscleral cyclophotocoagulation: a retrospective observational analysis

  • By

  • Mitsuya Otsuka

  • Nobuo Ishida

  • Gaku Ishida

  • Teruhiko Hamanaka

  • Ryota Akai

  • Yasuhito Nitta

  • Atsushi Hayashi

  • March 2, 2026

Share

  • 1

    Micropulse transscleral cyclophotocoagulation (MP-TSCPC) effectively reduces intraocular pressure (IOP) in refractory glaucoma cases.

  • 2

    The study aimed to evaluate the correlation between mid-term aqueous flare levels and IOP reduction after MP-TSCPC.

  • 3

    A total of 25 patients with measurable aqueous flare values were included in the retrospective analysis.

  • 4

    Postoperative flare measurements were taken at multiple time points, and IOP was primarily measured using Goldmann applanation tonometry.

  • 5

    The findings suggest a potential association between sustained flare elevation and IOP reduction during the mid-term follow-up.