External validation of the international IgA nephropathy prediction tool in a Thai cohort - Takeaways - MDSpire

External validation of the international IgA nephropathy prediction tool in a Thai cohort

  • By

  • Atthaphong Phongphithakchai

  • Attamon Thongrueang

  • Thatsaphan Srithongkul

  • Sukit Raksasuk

  • Fumitaka Kawakami

  • Aman Tedasen

  • Moragot Chatatikun

  • June 18, 2026

  • 0 min

Share

  • 1

    The study externally validated the International IgA Nephropathy Prediction Tool in a Thai cohort with biopsy-proven IgA nephropathy.

  • 2

    A total of 133 patients were followed for a median of 3.4 years, with 33.8% reaching the renal endpoint.

  • 3

    The IIgANPT showed good discrimination with C-statistics of 0.753 and 0.754 for models with and without race, respectively.

  • 4

    Calibration was preserved, but confidence intervals around calibration slopes were wide, indicating limited precision.

  • 5

    Both model versions performed similarly, suggesting the race variable's exclusion had minimal impact on prognostic performance.

Original Source(s)